Study of Calcium Chloride Dissolved Water under the Effect of Magnetic Field

Study of Calcium Chloride Dissolved Water under the Effect of Magnetic Field



Gunvir Kaur, P.S.Tarsikka 



Life and water are linked closely as it is essential
for life to begin and for life to live on. Water passes through soil and
aquifers often come in contact with minerals which at the correct
environmental conditions, dissolve in the ground water to make it hard.
The high mineral content water is normally not dangerous to human’s
health, but it causes many household problems which makes it less
desirable. A physical technique using magnetic field to purify water is
cheap, require no energy to run and create no pollutants but the
efficiency of this treatment is still a controversial question. In
present study, the physical parameters like total dissolved salts (TDS),
electrical conductivity (EC) and pH have been evaluated in magnetized
(0.05T – 0.20T) calcium chloride solution. Data collected during the
experiment was analyzed statistically (SPSS-20.0). This analysis shows
that the increase in TDS, EC and pH under the effect of magnetic field
was significant (p < 0.01). The regression analysis was used to show
linear relation between TDS and EC of water.



10.22161/ijeab/1.4.50



http://ijeab.com/upload_document/issue_files/50%20IJEAB-DEC-2016-43-Study%20of%20Calcium%20Chloride%20Dissolved%20Water%20under%20the%20Effect%20of%20Magnetic%20Field.pdf



http://ijeab.com/submit-paper/

Comments

Popular posts from this blog

The Ecological Impacts of Light Pollution at Night-time a Mechanistic Appraisal

Studying the tendency of citizens to participate in the protection and development of land scape in Tehran

Land Use Land Cover Change Detection by Using Remote Sensing Data in Akaki River Basin